PVB Moisture Test Equipment

  • PVB moisture test equipment
  • Heat resistance test boiling device
  • Building safety glass material boiling test water bath instrument
  • Laminated glass boiling tester

Standard:

  • EN ISO 12543-4 architectural glass-laminated glass and laminated safety glass-part 4: durability test method-clause 5 high temperature test
  • AS/NZS 2208 Building Safety Glass Material-Appendix F Boiling Test
  • GB 15763.3 Building safety glass material Part 3: Laminated glass-7.8 Heat resistance test
  • ANSI Z97.1 safety glass materials used in buildings-safety performance specifications and test methods-clause 5.3.2-(1) boiling test
  • ECE R43 Uniform Provisions Concerning Approval of Safety Glass Materials and Their Installation on Vehicles
  • Power: 220V 50Hz 3Kw (customizable)
  • External dimensions: 430mm * 290mm * 575mm
  • Internal size: 400mm * 255mm * 480mm
  • Frame: 340mm * 235mm * 350mm
  • 300mm * 300mm up to 6 samples

Range:

Determine the effect of safety glass materials exposed to temperature and humidity by boiling

principle:


Immerse the specimen in hot and boiling water for the specified time, and check for bubbles and other defects

instrument:


The device includes two water baths, each of which is large enough to maintain the test sample vertically and completely submerged on the edge for duration testing

sample:


Three specimens of 300mm * 300mm size with the same thickness as the impact specimen shall be tested. These specimens can be cut from production samples of size and thickness submitted for impact testing. Samples can be cut from similar annealed laminated glass originals

program:


1): Immerse the vertical edge of the sample in a water bath with a temperature of 66°C±3°C for 3 minutes
2) Quickly transfer the specimen to a water bath that maintains its boiling point. Immerse the sample vertically into the edge for 2 h
3) Take out the sample and check for bubbles and other defects

Related products

Contact Us

0335-7963298